How Do Engineers Test Image Quality in Medical Imaging Equipment?


Image quality is one of the most important factors when evaluating medical imaging equipment. Whether it is an MRI scanner, CT scanner, X-ray system, ultrasound machine or another diagnostic imaging device, the quality of the images directly affects the ability of healthcare professionals to interpret anatomical structures and identify abnormalities.

But how do engineers actually determine whether an imaging system is producing good-quality images?

Medical imaging engineers and service specialists use a combination of quality assurance (QA), performance testing, calibration, standardised test objects and technical measurements to evaluate whether equipment is operating within its expected specifications.

For hospitals, diagnostic centres and private healthcare providers in the UK, understanding these processes can provide valuable insight when purchasing, maintaining, upgrading or refurbishing imaging equipment.

Why Is Image Quality Testing Important?

Medical imaging systems operate using complex combinations of hardware and software. Over time, components can experience wear, calibration changes or performance variations.

For example, an X-ray tube may deteriorate, an MRI system may develop performance issues, or a CT detector may not perform within expected tolerances.

Image-quality testing helps identify these issues before they become significant clinical problems.

The objective is not simply to produce an attractive-looking image. Engineers need to determine whether the system can consistently produce images with appropriate contrast, resolution, uniformity, noise and other performance characteristics.

Engineers Use Test Phantoms

One of the most common methods of evaluating medical imaging performance is the use of a phantom.

A phantom is a specially designed object that simulates particular imaging characteristics of the human body.

Instead of scanning a patient, engineers can scan a standardised phantom and analyse the resulting images.

Different phantoms are designed for different imaging modalities.

For example, CT phantoms can be used to assess parameters such as noise, uniformity and low-contrast performance, while MRI phantoms can help evaluate signal uniformity and other system characteristics.

Testing Spatial Resolution

Spatial resolution refers to the ability of an imaging system to distinguish small structures that are close together.

Higher spatial resolution allows finer anatomical details to be separated more clearly.

Engineers can use test patterns or phantom structures containing objects with known dimensions.

The resulting image is examined to determine whether the scanner can resolve the expected structures.

Spatial resolution is particularly important for applications where small anatomical details matter, including bone imaging, lung imaging and certain high-resolution MRI examinations.

Testing Contrast Resolution

Another important measurement is contrast resolution.

Contrast resolution describes the system's ability to distinguish between tissues or structures that have relatively small differences in signal or attenuation.

This can be especially important for soft-tissue imaging.

Engineers may use phantom objects with different contrast levels to determine how effectively the system can identify low-contrast structures.

In CT, for example, low-contrast detectability can be influenced by image noise, dose, reconstruction algorithms and scan parameters.

Measuring Image Noise

Image noise appears as unwanted variation or graininess within an image.

Too much noise can make it difficult to distinguish subtle anatomical structures.

Engineers can measure noise using standardised phantom images and statistical analysis.

The exact methodology varies according to the imaging modality and testing protocol.

For CT, noise may be measured in a uniform phantom region. For MRI, signal and noise measurements can be used as part of broader performance testing.

Maintaining appropriate noise levels is particularly important because image noise can affect diagnostic confidence.

Signal-to-Noise Ratio

MRI performance is often discussed in terms of signal-to-noise ratio (SNR).

SNR represents the strength of the useful MRI signal relative to background noise.

A higher SNR can provide more useful information for image formation, although image quality always needs to be considered in the context of scan parameters, spatial resolution, acquisition time and the clinical application.

Engineers can use controlled phantom examinations to monitor whether the system's performance remains consistent over time.

Uniformity Testing

Uniformity is another important aspect of image quality.

Ideally, a uniform phantom should produce a relatively consistent image throughout the region being assessed.

Unexpected variations may indicate issues involving hardware, calibration, coils, detectors or other components.

MRI quality assurance programmes, for example, can include tests designed to identify signal-intensity variations across the imaging field.

Regular testing can help detect changes before they develop into larger equipment problems.

CT-Specific Image Quality Testing

CT scanners have several performance characteristics that engineers can evaluate.

These may include:

  • CT number accuracy
  • Image noise
  • Uniformity
  • Spatial resolution
  • Low-contrast performance
  • Artefacts
  • Slice thickness
  • Radiation output
  • Geometric accuracy

A CT phantom can contain materials designed to produce known attenuation values. Engineers can compare measured results against expected values and applicable testing criteria.

This provides an objective way of monitoring scanner performance.

X-Ray Image Quality Testing

For conventional X-ray and digital radiography systems, engineers can assess factors such as:

  • Spatial resolution
  • Contrast performance
  • Exposure consistency
  • Detector performance
  • Artefacts
  • Automatic exposure control
  • Radiation output

Digital radiography systems also require attention to detector calibration and image-processing behaviour.

The objective is to ensure that the system provides consistent diagnostic imaging while operating within appropriate exposure parameters.

Ultrasound Image Quality Testing

Ultrasound systems are different because they use sound waves rather than X-rays or magnetic fields.

Engineers and service specialists can use ultrasound test phantoms to assess characteristics such as:

  • Depth of penetration
  • Spatial resolution
  • Uniformity
  • Dead-zone performance
  • Distance accuracy
  • Cyst or lesion detectability

The transducer is particularly important because it generates and receives the ultrasound signal.

A damaged or deteriorating transducer can significantly affect image quality.

What About Artefacts?

Engineers also look for image artefacts—features that appear in an image but do not represent actual patient anatomy.

Artefacts can have many causes.

They may result from hardware problems, patient motion, incorrect calibration, electromagnetic interference, reconstruction issues, metal objects or other technical factors.

The pattern of an artefact can sometimes provide valuable clues about its underlying cause.

Regular quality assurance helps identify persistent artefacts that may indicate an equipment issue.

Image Quality Is Not Just About Sharpness

It is important to understand that the sharpest-looking image is not necessarily the best clinical image.

Medical imaging involves balancing several factors.

For CT, for example, increasing image detail may influence noise and radiation dose depending on the protocol and reconstruction approach.

In MRI, higher spatial resolution can affect acquisition time and signal.

Therefore, engineers evaluate multiple performance parameters rather than relying on one visual characteristic.

Acceptance Testing and Routine Quality Assurance

Image-quality testing is particularly important when new equipment is installed or when an existing system undergoes major servicing.

Acceptance testing helps establish whether equipment performs according to agreed specifications and applicable requirements when introduced into clinical service.

After installation, routine quality assurance testing can monitor performance over time.

Comparing current results with previous baseline measurements can help identify gradual changes in equipment performance.

Why Image Quality Testing Matters When Buying Used or Refurbished Equipment

For healthcare providers considering refurbished or pre-owned imaging equipment, technical evaluation is especially important.

A scanner's age alone does not tell the complete story.

The condition of the equipment, service history, software configuration, component performance and image quality all need to be considered.

Appropriate technical testing can help establish whether an imaging system is operating as expected before it is placed into service.